Although intended primarily for electrical distribution networks, IEC can be used for other metering applications, including non-electrical metered. 4 Jan Table I.3 – Meter Reading: Mapping ebIX Metered Data to IEC .. intended primarily for electrical distribution networks, IEC can be. IEC Edition INTERNATIONAL. STANDARD. Application integration at electric utilities – System interfaces for distribution management –.

Author: Tygojin Yozshular
Country: Austria
Language: English (Spanish)
Genre: Music
Published (Last): 25 November 2006
Pages: 11
PDF File Size: 2.15 Mb
ePub File Size: 12.53 Mb
ISBN: 685-3-71814-722-4
Downloads: 97054
Price: Free* [*Free Regsitration Required]
Uploader: Tojakora

An EndDeviceGroup is used for grouping end devices for a variety of purposes including, but not limited to, load control and other types of demand response. Load eic devices are used to control loads at a ServiceDeliveryPoint. Secondary voltage or current values are those that are often measured directly by the meter.

The tasks of the Data Collection sub-component within the Metering System may include: Still another approach is to interface with a customer Energy Iecc System which would be another type of end device.

The specific details of communication protocols those systems employ are outside the scope of this standard. Meter Maintenance and Asset Management. This type of information typically joins customer call-ins in the OMS to allow it to better predict the location of the outage. Given that a meter will have metrology capability, it will in all likelihood meter kWh, but possibly also demand, reactive energy and demand, Time Of Use quantities, Interval Data, Engineering quantities, and more.

It looks like your browser does not have JavaScript enabled. 619689 1 of this standard describes infrastructure services common to all abstract components while Parts define the details of the information exchanged for specific types of abstract component. A meter service request is a type of work that can be used for a variety of meter service related activities.

  STUDIUL CHINA CARTE DE BUCATE PDF

Utilities may promote particular programs to their industrial, commercial, agricultural, and residential customers in an effort to encourage a particular behaviour, or to make them aware of their options. End Devices with LC functionality can take on different forms.

End point install, configure, remove, repair, disconnect, reconnect. The end device itself, while presenting a myriad of functionality, is not the subject of this standard. This series of standards is intended to support applications that need to exchange data every few seconds, minutes, or hours rather than waiting for a nightly batch run. Commercial and Industrial meters often employ 619968-9 transformers and voltage transformers to meter the actual service.

A set of values obtained from the meter. The MeterAsset class is used to describe meters.

IEC | IEC Webstore

The IEC series of standards is intended to facilitate inter-application integration as opposed to intra-application integration. Usually all the attributes of these classes are contained within a message type. Message types related to the exchange of information for documents related to meter reading and control. The CommunicationsAsset class is used to represent a communications device that is attached to a piece of conducting equipment.

It is not the intention of this standard to define the applications and systems that vendors should produce. The CIS is also often involved with processes related to billing inquires, meter disconnect and meter reconnect, rate program changes. Documents that contain provisions which, through reference in this text, constitute provisions of this International Standard.

The purpose of this document is to define a standard for the integration of Metering Systems MSwhich includes traditional manual systems, and one or two-way Automated Meter Reading AMR Systems, with other systems and business functions within the scope of IEC The interaction between systems is within the scope of this standard, and Figure 2 attempts to describe the exact systems involved, and provide an overview to the stakeholder landscape.

  JAB COMIX AMERICUNT DRAGON PDF

Although intended primarily for electrical distribution networks, IEC can be used for other metering applications, including non-electrical metered quantities necessary to support gas and water networks.

Interface Standard for Meter Reading and Control. A Work Management system is responsible for work that is performed by field resources. The software inventories the asset — providing a record of its physical attributes as well as its location. A Load Management System may perform load forecasting, contingency 619668-9, and other simulations prior to issuing a load control command.

IEC Part 9: Another approach is to use meters that have relays which are configured to serve as LC devices. As used in IECa Distribution Management System DMS consists of various distributed application components for the utility to manage electrical distribution networks.

Asset Management is treated categorically in This set of standards is limited to the definition of interfaces and is implementation independent. This can be done for both economic and emergency reasons. About Us Google Facebook Site. CIM extensions needed for meter reading and control.

For dated references, only the editions cited apply. A message encapsulates a General operation. Readings may have one or more MeasurementQuality indicators. Classes described as type “Part” are lower level entities that are associated with a containing document.